Commercial rooftop photovoltaic modules with visible mounting rails and clamps.

Mounting systems

Secure mounting for rooftop and ground arrays.

Rooftop and ground-mount equipment selected for module dimensions, roof type, site conditions and installation plan.

  • Project-matched selectionEquipment, quantities and interfaces reviewed with your team
  • U.S. warehouse inventoryDirect delivery to your specified U.S. location
  • Documentation supportCertification documents for the selected equipment

Share your project location, quantities and target schedule — we confirm availability and a tailored quotation.

Complimentary design supportEquipment scope and system planning
U.S. warehouse inventoryDirect delivery to agreed locations
Certification documentsProvided for the selected equipment
Built for B2BInstallers · EPCs · Contractors · Distributors

Category overview

Clear specifications. Practical supply.

Rooftop and ground-mount equipment selected for module dimensions, roof type, site conditions and installation plan. Our team can review quantities, interfaces, documentation and delivery requirements with your installer, EPC or purchasing team.

  • ApplicationsResidential roofs, commercial rooftops and ground-mounted arrays
  • SelectionRail, clamp, attachment, tilt and site-condition requirements
  • SupplyU.S. warehouse inventory with direct delivery for qualifying domestic orders

Next step

Review the right fit for your project.

Product selection and delivery terms are confirmed in writing for each destination and application.

Send Your Requirements →

Quality, documentation & supply review

Quality, documentation and site-fit review.

Module compatibility, support arrangement, site conditions and requested documentation are reviewed against the proposed mounting scope before the equipment scope is confirmed.

Model-specific technical review

Module fit, structure type, environment and fastening requirements are reviewed for the proposed system.

Documentation fit

Requested data sheets, technical documents and compliance information are reviewed for the proposed model and destination-market requirements.

Quote-confirmed supply scope

Model, quantity, accessories, availability, delivery conditions and requested documents are confirmed in the written quotation.

Clear, project-specific information. Documentation availability and applicability are confirmed for the proposed equipment rather than assumed across a whole product category.

Project-fit mounting planning

Start with the roof or ground condition, then match the mounting package.

Mounting hardware has to work with the actual structure, module format and local exposure conditions. We help convert site information into the appropriate mounting supply scope.

01

Structure & surface

Roof type or ground condition, attachment approach, penetrations and usable installation area.

02

Module & layout

Module dimensions, array geometry, tilt requirements and rail or clamp compatibility.

03

Site exposure

Wind, snow, corrosion environment, local requirements and installer preferences where provided.

Utility-scale solar array mounted on ground-fixed structures.

Configuration context

Let the structure guide the mounting scope.

The mounting package follows the real roof or ground condition, module dimensions, array geometry and local exposure information supplied by the project team. It is not selected independently of the installation plan.

  • Project inputRoof or ground condition and usable area
  • Array fitModule dimensions and layout geometry
  • Site contextExposure conditions and installation approach

SPECIFICATION & PROCUREMENT

Plan your equipment purchase.

Review the specification, configuration, documentation and delivery scope together before selecting equipment.

MaterialsAnodised aluminium (AL6005-T5), hot-dip galvanised steel, stainless fasteners
ApplicationsPitched roof, flat roof ballasted, ground screw, carport, tracker-ready
Design loadsEngineered to your site conditions, including wind speeds up to 60 m per second

Illustrative selection information. Confirm the final specification for your model, site and delivery scope.

Specifications at a glance
MaterialsAnodised aluminium (AL6005-T5), hot-dip galvanised steel, stainless fasteners
ApplicationsPitched roof, flat roof ballasted, ground screw, carport, tracker-ready
Design loadsEngineered to your site conditions, including wind speeds up to 60 m per second
StandardsAS/NZS 1170, EN 1991 (Eurocode 1), JIS, or your local code
FinishAnodised 10 microns or more, or galvanised 65 microns or more
AdjustabilityFixed tilt, adjustable tilt, and seasonal tilt options
Warranty15 years
Grades you can order
GradeConfigurationWhere it is usually specified
Pitched-roof railAnodised aluminium rail, adjustable tile and shingle hooksResidential and small commercial pitched roofs
Standing-seam clampNon-penetrating seam clamps in aluminium or stainless steelMetal roofs where roof penetrations are not permitted
Flat-roof ballastGalvanised steel or aluminium tray, 5 to 10 degree tilt, ballast zonedFlat commercial roofs with no penetration allowed
Ground pile or screwHot-dip galvanised steel or aluminium, driven pile or ground screwOpen land, uneven terrain, sites that will be decommissioned later
Carport and trackerGalvanised steel structure designed to your wind and snow regionParking canopies and single-axis tracker rows
Packaging, MOQ and shipping
StockStandard rails, clamps and fittings held in U.S. warehouse inventory
Minimum orderFrom one pallet or bundle
DeliveryDirect delivery to your specified U.S. address
Quotation basisPriced by weight (kg) rather than piece count
Lead timeAs fast as 7 days for stocked items
ShippingU.S. domestic freight; consolidated with your module delivery
Documents supplied with every order
  • Site-specific structural calculation report issued with every project
  • Material certificates and coating thickness report
  • Shop drawings, Bill of Materials and installation manual
  • Torque specifications and maintenance notes

Ordering questions

Can you design to our local wind and snow code?

Yes. A site-specific structural calculation comes with every project — send the wind speed, snow load and building height and we return a stamped calculation for that location, not a generic sheet.

Do you supply rails and clamps separately?

Yes. Full kits and individual components are both available, which matters when you are replacing or extending an existing array.

Which roof types do you cover?

Pitched tile, metal standing seam, trapezoidal metal, flat ballasted and membrane roofs. Tell us the roof build-up and we match the fixing and flashing to it.

What is the MOQ for mounting?

From one pallet or bundle, and mounting is most cost effective when it travels with your module order on the same delivery.

Aluminium or galvanised steel?

Aluminium is lighter and corrosion resistant, which suits weight-limited roofs. Hot-dip galvanised steel carries higher loads and suits ground-mount and carport structures. Coastal sites are specified in stainless steel or with a heavier coating, and we tell you which applies.

What information do you need to design the structure?

Wind speed, snow load, building height, roof covering and pitch, and the module dimensions you intend to use. With those we return a site-specific structural calculation for that location.

Other equipment in this range

Solar modulesInverters and controllersBattery energy storageTransformersSwitchgear and distribution

Every document, certification and service level above is what we commit to on your order. Where a figure depends on the model you select or the destination market, we state the exact value in writing on the quotation before you pay.

Scroll to Top