Solar modules, inverter, battery storage, mounting, transformer and switchgear equipment lineup.

Product supply

Solar and electrical equipment.

Six product categories for residential and commercial projects. Share your requirements for model selection and a tailored quotation.

  • Project-matched selectionEquipment, quantities and interfaces reviewed with your team
  • U.S. warehouse inventoryDirect delivery to your specified U.S. location
  • Documentation supportCertification documents for the selected equipment

Share your project location, quantities and target schedule — we confirm availability and a tailored quotation.

Complimentary design supportEquipment scope and system planning
U.S. warehouse inventoryDirect delivery to agreed locations
Certification documentsProvided for the selected equipment
Built for B2BInstallers · EPCs · Contractors · Distributors

Our product range

The equipment your project needs.

Six clear categories. Product selection, documentation and availability confirmed for your requirements.

Solar module category

Solar Modules

PV module options selected around output, dimensions and project specifications.

View Solar Modules →
Battery energy storage category

Energy Storage

Battery and storage configurations reviewed for capacity, operating needs and compatibility.

View Energy Storage →
Solar mounting rails and balance-of-system components

Mounting Systems

Rooftop and ground-mount equipment selected for module dimensions and site conditions.

View Mounting Systems →
Transformer and substation equipment

Transformers

Transformer equipment specified around project capacity, voltage and distribution requirements.

View Transformers →

Certification & documentation

Documentation support for every product category.

For modules, inverters, storage, mounting, transformers and switchgear, we review the relevant product certification and compliance documents against the selected model and destination-market requirements.

  • Model-specific reviewCertificates and compliance documents are confirmed for the actual equipment proposed.
  • Destination requirementsDocumentation is checked against the standards and market requirements supplied with your enquiry.
  • Quote with clarityRequest the required documents alongside your product list, quantities and delivery location.
Solar product certification marks including TÜV, CE, ISO and UL
Certification documentation is confirmed by product model and destination.

SERVICE & QUALITY

What every order includes

Applies to equipment supplied through GTP Solar across all six categories, from single pallets to project-scale releases.

On every equipment order

  • Specification sheets, nameplate data and test reports for the exact models supplied – not for a nearby model in the same family.
Order documents
  • Transformers and switchgear: drawings issued for your approval before production starts.
  • Packing list, commercial invoice and delivery documentation with every shipment.

Stock and lead time

  • Common specifications are held in U.S. warehouse inventory.
Stock & delivery details
  • As fast as 7 days on stocked lines, delivered direct to your U.S. job site or yard.
  • From one pallet on stocked module lines, with no minimum quantity on inverters and storage.

Compliance paperwork

  • Storage orders include the UL 9540 and UL 9540A documentation for the supplied model, the clearance drawing and the anchorage calculation for your region.
Compliance documents
  • Where your jurisdiction asks for more than the standard pack, we produce it before shipment.

These commitments apply to equipment supplied through GTP Solar. Where a manufacturer term is longer, the manufacturer term applies instead. Ask for any of them in writing on your quote. See the full service and quality commitment.

SELECTION GUIDE

How the equipment categories fit together

Each category decides one thing in the system. Specifying them in this order keeps the interfaces consistent and avoids the rework that comes from ordering them separately.

Solar modulesSets how much energy the site can produce per square metre
Inverters and controllersConverts DC to usable AC and manages battery charging
Battery energy storageDecides how long the load runs without sun or grid

Illustrative selection information. Confirm the final specification for your model, site and delivery scope.

View full configuration & sizing factors
EquipmentWhat it decides in the systemSpecified from
Solar modulesSets how much energy the site can produce per square metreRoof or land area, racking format, inverter string voltage and current window
Inverters and controllersConverts DC to usable AC and manages battery chargingArray configuration, grid code of the utility, battery chemistry and backup requirement
Battery energy storageDecides how long the load runs without sun or gridWhich circuits must stay on, for how long, and the cycling profile
Mounting systemsHolds the array to the structure for the design lifeWind speed, snow load, roof covering, building height, ground conditions
TransformersMatches system voltage to the grid or plant voltageLoad profile and diversity, fault level, indoor or outdoor, losses specified by the utility
Switchgear and distributionProtects and isolates every circuit downstreamProspective fault level, discrimination study, required form of separation, maintenance policy

Indicative ranges for enquiry planning. Final values follow the site review and are confirmed in writing on your quote.

Where orders usually go wrong

  • Modules ordered before the inverter string window is checked, so the string configuration has to be redone on site.
  • Storage ordered after the electrical design is frozen, which puts fire-code review on the critical path.
  • Transformer and switchgear bought from different suppliers, so impedance and short-circuit ratings do not line up.
  • Mounting ordered on price alone, without the structural calculation for the wind and snow region of the site.

Questions buyers ask

Can we order one category now and the rest later?

Yes, but interfaces are easier to get right if the full scope is reviewed once. We can hold the design and release the equipment in the sequence your schedule needs.

How do we avoid mismatched equipment between suppliers?

By specifying the interfaces before ordering: string voltage and current window, battery communication protocol, transformer impedance and vector group, switchgear fault rating. We confirm each one in writing on the quotation.

Is everything stocked in the U.S.?

Common specifications are held in U.S. warehouse inventory and can ship in as little as 7 days. Engineered ratings, such as transformers built to order, are quoted with a firm date.

What documents arrive with the equipment?

Datasheets, test reports and certification for your destination market, serial-level test records where applicable, packing list and delivery documentation. The exact list is on each product page.

Send the application, target capacity and destination, and we will return a single equipment list with the interfaces confirmed rather than six separate quotations.

Scroll to Top